Command Line Interface Guide
220 omconfig storage Commands
omconfig storage pdisk action=blink controller=1
pdisk=0:0
• For SAS controllers:
omconfig storage pdisk action=blink controller=1
pdisk=0:2:0
NOTE: On a SAS controller, the physical disk resides in enclosure 2.
omconfig Unblink Physical Disk
You can disable the light (light emitting diode or LED display) on one or
more physical disks attached to a controller. Use the following omconfig
command syntax to unblink one or more physical disks.
Complete Syntax
omconfig storage pdisk action=unblink controller=
id pdisk=<PDISKID>
where id is the controller ID. The <PDISKID> variable specifies the
physical disk.
To obtain these values, type omreport storage controller to display the
controller IDs and then type omreport storage pdisk controller=ID to
display the IDs for the physical disks attached to the controller.
Example Syntax
To disable the LED on physical disk 0 on connector 0 of controller 1:
• For SCSI, SATA, and ATA controllers:
omconfig storage pdisk action=unblink controller=1
pdisk=0:0
• For SAS controllers:
omconfig storage pdisk action=unblink controller=1
pdisk=0:2:0
NOTE: On a SAS controller, the physical disk resides in enclosure 2.