Command Line Interface Guide
omconfig: Managing Components Using the Instrumentation Service 165
Table 4-25 lists the valid parameters for the command.
NOTE: Alert settings are mutually exclusive and you can set one at a time only.
The action settings are also mutually exclusive and you can set one at a time only.
However, alert and action settings are not mutually exclusive of each other.
Table 4-26 lists the components and events for which you can set platform
events. Components are listed in alphabetical order, except that warning
events always precede failure events for a component.
Table 4-25. Parameters for Alert Action Command
Action Description
action=disable Disables the SNMP alert.
action=enable Enables the SNMP alert.
action=none Takes no action when the system is hung or has crashed.
action=powercycle Turns off the electrical power to the system, pauses, turns the
power on, and reboots the system.
action=poweroff Turns off the electrical power to the system.
action=
powerreduction
Reduces the processor speed until the power consumption
comes down and reaches below the warning threshold. If the
system power consumption stays below the warning
threshold, increases the processor speed.
NOTE: This action is applicable only for PowerEdge Rack and
Tower systems earlier than PowerEdge
yx1x
systems.
action=reboot Forces the operating system to shut down and initiates system
startup, performs BIOS checks, and reloads the operating
system.