Command Line Interface Guide
152 omconfig: Managing Components Using the Instrumentation Service
omconfig chassis volts or omconfig mainsystem volts
Use the omconfig chassis volts or omconfig mainsystem volts command to
set voltage probe warning thresholds. As with the other components, you can
view both the warning and failure threshold values, but you cannot set the
failure threshold values. The system manufacturer sets the minimum and
maximum values for the failure thresholds.
Valid Parameters for Voltage Warning Thresholds
The following table displays the valid parameters for setting voltage warning
threshold values.
NOTE: Threshold values that you can set vary from one system configuration
to another.
Setting the Minimum and Maximum Warning Threshold Values to Default
To set both the maximum and minimum voltage warning threshold values to
the recommended default value, type:
omconfig chassis volts index=2 warnthresh=default
or
omconfig mainsystem volts index=2 warnthresh=
default
NOTE: You cannot default one value and set another. In other words, if you default
the minimum warning threshold value, you are also selecting the default value for
the maximum warning threshold value.
Table 4-16. Parameters of omconfig chassis volts or omconfig mainsystem volts
name=value pair Description
index=<n> Probe index (specify).
warnthresh=default Sets minimum and maximum warning threshold values
to default.
minwarnthresh=<n> Sets minimum warning threshold value (three decimal
places).
maxwarnthresh=<n> Sets maximum warning threshold value (three decimal
places).