Command Line Interface Guide
150 omconfig: Managing Components Using the Instrumentation Service
Usage of extipmiusergroup=custom
The following table displays the usage of extipmiusergroup=custom:
omconfig chassis temps or omconfig mainsystem temps
Use the omconfig chassis temps or omconfig mainsystem temps command
to set warning thresholds for temperature probes. As with other components,
you can view both warning and failure threshold values, but you cannot set
failure threshold values. The system manufacturer sets the minimum and
maximum failure threshold values.
NOTE: Threshold values that you can set vary from one system configuration
to another.
Valid Parameters for Temperature Warning Thresholds
The following table lists the valid parameters for setting temperature warning
thresholds:
Table 4-14. Parameters of omconfig chassis remoteaccess config=user id=<user id>
extipmiusergroup=custom or omconfig mainsystem remoteaccess config=
user id=<user id> extipmiusergroup=custom
name=value pair 1 name=value pair 2 name=value pair 3 Description
config=user id=user id
extipmiusergroup=
custom
NOTE: extipmiusergroup
user group is available only
on the Dell
yx0x
Blade
systems.
loginidrac= true |
false
configureidrac=
true | false
true or false: Enables
or disables logging
into iDRAC.
true or false: Enables
or disables
configuration of
iDRAC.
Table 4-15. Parameters of omconfig chassis temps or omconfig mainsystem temps
name=value pair Description
index=<n> Number of the probe or probe index (specify).
warnthresh=default Sets the minimum and maximum warning threshold
values to default.
minwarnthresh=<n> Sets the minimum warning threshold values (one
decimal place).
maxwarnthresh=<n> Sets the maximum warning threshold values (one
decimal place).