Command Line Interface Guide
omconfig: Managing Components Using the Instrumentation Service 127
Table 4-6 lists the valid parameters for the command.
NOTE: The options ipv4idrac, ipv6idrac, and macidrac are deprecated.
Table 4-6. Parameters of omconfig chassis frontpanel or omconfig mainsystem
frontpanel
name=value pair 1 name=value
pair 2
Description
lcdindex=<index> NA Specifies the LCD line number.
config=none | default
| custom
NA none: Sets the LCD text to none.
default: Sets the LCD text to default.
custom: Sets the LCD text to custom.
text=<custom text> NA Sets the custom text for LCD when config=
custom.
nmibutton=enable |
disable
NA enable: Enables the NMI button on the system.
disable: Disables the NMI button on the system.
powerbutton=enable |
disable
NA true: Enables the Power button on the system.
false: Disables the Power button on the system.
config=sysname NA Sets the name of the system.
config=syspower NA Sets the system power information.
config=servicetag NA Sets the system service tag information.
config=
remoteaccessipv4
NA Sets the remote access IPv4 information.
config=
remoteaccessipv6
NA Sets the remote access IPv6 information.
config=
remoteaccessmac
NA Sets the remote access MAC address.
config=ipv4idrac Sets IPv4 DRAC information.
config=ipv6idrac Sets IPv6 DRAC information.
config=macidrac NA Sets the DRAC’s MAC address.
config=ambienttemp NA Sets the system temperature in centigrade.
security=modify NA Allows you to modify the LCD text.
security=view NA Provides read-only access to the LCD text.
security=disabled NA Provides limited access to the LCD text.
remoteindication=true NA LCD flashes when the system detects an active
remote session.