Release Notes
Microsoft Windows Server 2012 x64 Essential Edition
Microsoft Windows Server 2008 x64 Enterprise Edition R2–SP2
Microsoft Windows Server 2008 x64 Standard Edition R2–SP2
Microsoft Windows 7 Professional and Enterprise
Microsoft Windows 8 Professional and Enterprise (x64 recommended)
Red Hat Enterprise Linux Server 6.5 x86_64
Red Hat Enterprise Linux Server 6.6 x86_64
Red Hat Enterprise Linux Server 7.0 x86_64
SUSE Linux Enterprise Server 11 SP3 x86_64
SUSE Linux Enterprise Server 12 x86_64
Web Browsers
OpenManage Power Center supports the following web browsers:
Mozilla Firefox Version 37 and 38
Google Chrome Version 41 and 42
Microsoft Internet Explorer Version 10 and 11
What’s New
Support for PowerEdge FX2/FX2s Chassis power monitoring and management.
Support for additional PDU models.
View and analyze the subsystem power and Compute Usage for Second (CUPS) values.
Analyze the server power characteristics per server model for planning and future expansion.
Display PDU socket connection mapping with the device.
Assist in planning capacity expansion and provide placement suggestions.
Identify the underutilized servers in the data center based on power consumption pattern.
Help to identify the potential cooling concerns in the data center.
Schedule OMPC database backup. The backup data can be used as a restore point in case of a disk failure.
View real-time system airflow history of the Dell’s 13th generation of PowerEdge servers.
Replicate the data center hierarchy on the iDRAC location based on OMPC physical location modelling.
21 pre-defined templates to create, customize, run and export reports.
Modified filters to customize the results based on distinctive needs and environment.
Fixes
BITS171946: The event description is divided into two columns in exported file.
BITS171806: Wrong time for power task, when user edit a schedule start time in DST.
BITS171761: One occurrence of recurrent power task may insert multiple entry in task list.
BITS171751: Configuring HTTPS port and Database port to the same one not blocked in installation wizard.
Known Issues
Issue 1: Only one device can be selected for analyzing, when the IP Address/Hostname is the same.
Description: The IP Address/ Host name will be NA while adding some of the Non Dell Chassis to OMPC. We use IP/Hostname as
key to identify the server hence cannot distinguish the device.
Resolution: No work around is available at this point of time. Low utilization and power utilization analysis functionality will be
limited if the device does not have unique IP Address/Host name.