Release Notes

Known Issues
Issue 1: The event description is divided into two columns in exported file
Description: Some event description can contain the comma “,” in events.This is breaking
the .csv file formatting. [171946]
Resolution: Please edit the CSV file manually and merge the columns.
Issue 2: Wrong time for power task, when user edit a schedule start time in DST
Description: Edit power task time in UTC -8 time zone will have time difference in the
summary page. [171806]
Resolution: Recommended to delete and recreate the power task if you need a change in the
specified time zone.
Issue 3: One occurrence of recurrent power task may insert multiple entry in task list.
Description: It’s a timer issue and it will not impact on the power action on the machine if if
user found more than one power tasks were add in the task list for a few times. [171761]
Resolution: Not Applicable
Issue 4: Configuring HTTPS port and Database port to the same one not blocked in installation
wizard
Description: Configuring same ports for HTTPS and database will cause Power Center
application launch failure after installation. [171751]
Resolution: Users can go ahead with the default values or do not provide same port for HTTPS
and database configuration
Limitations
Issue 1: The power graph is blank when viewing the power (or temperature) history
Description: When viewing the power history (or temperature) of a selected group in the 15
minute/1H window, the graph is blank.
The possible cause: OpenManage Power Center has just been installed and has not collected
enough data to provide a power history graph.
Resolution or workaround: N/A. Wait until OpenManage Power Center has collected enough
data to present the graph properly.
Issue 2: Getting”Average inlet temperature” events on an empty group
Description: There is no device in the group, why is the event generated? The event is
generated because you set the “Min Warning threshold” or “Min critical Threshold” values, but
there are no devices present in the group. The temperature is reported as ‘0’ in an empty group,
and hence the event is generated.
Resolution or workaround: This is not recommended practice. You should only set the
temperature or power threshold on groups that contains devices.