Owner's Manual

Field Description
PDU
UPS
Chassis
Unsupported
Group Device’s physical group.
Size of Device Physical size of device in rack units (U)
Faceplate Power Device faceplate power
De-rated Power Device de-rated power
IP Address Device IP address
Serial Number or Service Tag Device serial number or service tag
Service Tag: The service tags for Dell chassis and
servers
Serial Number: The serial numbers for Dell PDU
and UPS devices
NA: For all other devices, NA is displayed
Asset Tag Device asset tag
Device Model Device model—for example, PowerEdge M610
Protocol Protocol used for communication, including:
IPMI
SNMPv1v2c or SNMPv3
WS-MAN
Power Capability Power monitoring and capping capability, or whether the
device can be upgraded, including:
Unknown
None
Monitor
Monitor & Capping
Monitor and Upgradable
Time of Discovery Time the device was discovered
Description Device description
NOTE: If a device is already discovered and listed in the Devices page, when Power Center runs a discovery task
and this device is discovered again, all the device information for this device is updated in the Devices page. For
more information on device discovery, see Adding a Device from the Network.
Adding A Device From The Network
You can use the Power Center management console to discover a device from the network.
NOTE: Power Center server tries to get device names from the DNS server specified in the network configuration
of the operating system. This may cause the device name to be different from the actual one if the DNS server
resolves the device IP address to a different device name.
56