Owner's Manual
1. On the Define IP Range screen, click the Add Range task.
NOTE: IP addresses and Network masks should conform to the 255.255.255.255 format.
2. On the Define A New IP Range screen, enter a Beginning IP address, an End IP address, and a
Network Mask.
3. Click Finish to continue, or click Cancel to discard your entries and return to the Define IP Range
screen.
4. Select one or more Connection Protocols:
– If the connection protocols you want to use are listed already, select them and then click Next.
– If the correct protocols are not listed, add a new protocol:
1. Click Add in the task menu.
2. On the Protocol Information screen, enter a new Profile Name and Description.
3. In the Protocol Information section, select the protocol appropriate to the device you are adding.
Power Center supports the following connection protocol types, and includes several optional
settings:
NOTE: Get the correct protocol type and credential information from your device administrator.
The user name and password for the IPMI/WS-MAN protocol must be the same as those used
for the iDRAC/CMC web console.
• IPMI: Select IPMI protocol for the server.
– IPMI User Name: Maximum length is 16 characters.
– IPMI Password: Maximum length is 255 characters.
– IPMI Key: A string of 40 hex digits.
• WS-MAN: Select WS-MAN protocol for the chassis.
– WS-MAN User Name: HTTP basic user name, maximum length is 255 characters.
– WS-MAN Password: HTTP basic password, maximum length is 255 characters.
– WS-MAN Port: Default value is 443, or enter a port number from 1 to 65535.
– WS-MAN Validate Certificate: Optional. Enables device certificate validation.
NOTE: A trust certificate must be imported into the system before the WS-MAN
Validate Certificate option is enabled, or the communication may fail. For more
information on how to install the certificate using the Dell Chassis Management
Controller, see "Configuration – New SSL Server Certificate Configuration" in the
Using Windows® Remote Management (WinRM) to Remotely Manage Dell™
PowerEdge™ M1000e Using the Chassis Management Controller (CMC)
technical whitepaper. It can be downloaded from: http://
www.delltechcenter.com/page/dcim.modular.cmc.winrm.
• SNMP v1v2c: Select an SNMP protocol version from SMMPv1, or SNMP v2/v2c for the PDU
or UPS.
– SNMP Community String: Required. Maximum length is 255 characters.
• SNMP v3: Select SNMP v3 for the PDU or UPS.
– SNMP User Name: Required. Maximum length is 16 characters.
– SNMP Authentication Password: Maximum length is 255 characters.
49