Release Notes
Resolution: Launch the respective iDRAC console for the Dell PowerEdge Server host from the Nagios
XI to view the Power Supply Roll up status.
• Issue 3
Description: In "Dell Chassis I/O Module Status" service, value for "FabricType" is shown incorrectly as
"UNKNOWN, for few IO Modules when Dell PowerEdge M1000e chassis is discovered.
Version affected: Dell OpenManage Plug-in Version 1.0 for Nagios XI.
Resolution: Launch the respective chassis console for the Dell PowerEdge M1000e chassis host from
the Nagios XI to view the “FabricType”.
• Issue 4
Description: In "Dell Chassis power supply status" service, health status for one of the power supply
instance which is standby is shown as "UNKNOWN" when Dell chassis is discovered.
Version affected: Dell OpenManage Plug-in Version 1.0 for Nagios XI..
Resolution: Launch the respective chassis console for the Dell PowerEdge M1000e, Dell PowerEdge
VRTX, and Dell PowerEdge FX2/FX2s chassis host from the Nagios XI to view the health status of
standby power supply.
• Issue 5
Description: In "Dell Server Voltage Probe Status", service when one of the instance's actual status is
UNKNOWN, that instance will appear as CRITICAL instead of UNKNOWN while monitoring using
SNMP protocol with iDRAC firmware version lower than 2.30.30.30.
Version affected: Dell OpenManage Plug-in Version 1.0 for Nagios XI.
Resolution: Upgrade iDRAC firmware version to 2.30.30.30 or above.
• Issue 6
Description: In "Dell Server Voltage Probe Status" service, some of the Voltage instances will be
missing when Dell PowerEdge C6320 server is discovered using WS-MAN protocol with iDRAC
firmware version lower than 2.30.30.30.
Version affected: Dell OpenManage Plug-in Version 1.0 for Nagios XI.
Resolution: Upgrade iDRAC firmware version to 2.30.30.30 or above.
• Issue 7
Description: In "Dell Server Overall Health Status" service, Power Supply Status is shown as OK instead
of UNKNOWN, when Dell PowerEdge T130 or Dell PowerEdge C6320 server is discovered using
SNMP protocol, and when Dell PowerEdge DSS1510 server is discovered using SNMP or WS-MAN
protocol with iDRAC firmware version lower than 2.30.30.30.
Version affected: Dell OpenManage Plug-in Version 1.0 for Nagios XI.
Resolution: Upgrade iDRAC firmware version to 2.30.30.30 or above.
• Issue 8
Description: When Dell chassis is discovered using IPv6, then the RACADM specific attributes will be
displayed as "Not Available" for the following services when RACADM version lower than 8.3.0 is
installed:
– "Dell Chassis Fan Status" - Speed(RPM)
4