Release Notes

Issue 4:
Description:
IPv6 traps are not associated with corresponding Dell device in the Nagios Core console.
Version Affected:
Dell OpenManage Plug-in Version 1.0 for Nagios Core.
Issue 5:
Description:
In 'Dell Server Overall Health Status' service, the overall health status of Power supply and Fan of
the Dell PowerEdge FM120x4 and FC630 servers appears as unknown when Rack Style
monitoring is enabled in the Dell PowerEdge FX2 chassis and the server monitored using WS-
MAN protocol.
Resolution:
Open the corresponding iDRAC console to view the status of Power supply and Fan.
Version Affected:
Dell OpenManage Plug-in Version 1.0 for Nagios Core.
Issue 6:
Description:
In 'Dell Server Fan Status' service, the FQDD value for some of the Fans is not available when
monitored using SNMP protocol.
Resolution:
Open the corresponding iDRAC console to view the Fan details.
Version Affected:
Dell OpenManage Plug-in Version 1.0 for Nagios Core.
Issue 7:
Description:
In 'Dell Server CPU Status' service, the overall health status of CPU appears as unknown after
upgrading firmware from version 1.57.57 to version 1.66.65 or downgrading firmware from
version 1.66.65 to version 1.57.57 on R620 while monitoring using SNMP protocol.
Resolution:
Open the corresponding iDRAC console to view the status of CPU.