Web Client Guide

Resource Monitors | Monitoring
261
The editor has the following fields and settings to configure:
Condition Properties
Name
Enter a text identifier for the conditions.
Alert
Check this if you want Dell OpenManage Network Manager to emit an alert when the
monitor satisfies the conditions.
Trendable
Check if the conditions specified are trendable.
Severity
Specify the severity of the emitted alert, if any.
# of Occurrences
Enter the number of occurrences of what is specified in the
Condition Filter
to satisfy the Conditions.
Description
A text description for the conditions.
Condition Filter
Minimally, use this panel to select a condition, an operator and a value. If you want to use the
logical AND or OR operators with a second condition, click the green plus (+), and select a second
condition, operator and value. For example,
Packet Out Errors
greater than 200
AND
ifSpeed
greater than 10000
can be a set of conditions that only has to occur once to satisfy this monitor’s
condition.
Click
Save
to accept your edits, or
Cancel
to abandon them.