Web Client Guide

Event Processing Rules | Key Portlets
123
Entity Type: Interface, Logical interface
CAUTION:
To successfully retrieve Custom attributes, you must first create them. See Edit Custom Attributes on
page 89.
You can also configure more limited variables that are slightly more efficient in performance, if not
as detailed as those described in the following section.
For example, you can retrieve the following attributes:
{RedCell.Config.EquipmentManager_Custom1}
{RedCell.Config.EquipmentManager_Custom2}
{RedCell.Config.EquipmentManager_LastBackup}
{RedCell.Config.EquipmentManager_LastConfigChange} and
{RedCell.Config.EquipmentManager_HealthStatus}
NOTE:
If the entity does not contain/return these values, then the message [No data for <attribute name>]
appears in the email instead.
Basic Variables
Attribute Description Email Action Variable
Name The event / alarm name {Name}
Message Description from the event {Message}
Entity Name The entity (interface, card...) name {EntityName}
Equipment Manager
Name
The name of the equipment, parent or chassis. {EquipMgrName}
Device IP address the IP of the device in alarm {DeviceIP}
Entity Type Type of entity (Router, and so on) {EntityType}
Instance ID An identifier for the event {InstanceID}
Protocol Type Of originating alarm (SNMP, syslog, etc.) {ProtocolType}
Protocol Sub Type Inform, Trap, [blank] (for internal events) {ProtocolSubType}
Receive Time {RecvTime}
Region The mediation server partition name. {Region}
Severity 0 - cleared, through 6 - critical, from Alarm
Definition
{Severity}
Source IP address The IP of the component sending the alarm {SourceIP}