Users Guide
Device Prerequisites | Troubleshooting
OMNM 6.5.3 User Guide 733
• Mediation Server (or Application Server, if enabled as a Mediation Server) must be allowed
access on the device, either through its specific IP address(es) or by checking
Any IP address
under
Alarms > SNMP
Agents.
•
Security > Firewall
must have
SNMP, HTTP
and/or
HTTPS
, and
Te l n e t
and/or
SSH
and
RTCP
enabled both as
Input
and
Output
from the Server. If your system collects SNMP Traps
and syslog messages, select those for Output from Server only.
• You must confirm, or start, the SNMP agent (Master Agent) on the device under
Alarms >
Agent Status.
After modifying the alarm and security areas of the web manager, you need to access the
Communication Manager
command line interface (CLI) using telnet, the
Native Configuration
Manager
(from the main web management page) or use Avaya’s
Site Administration
software. If
telnetting to the CLI, choose the
w2ktt
terminal type upon login. You must have a
Communication Manager login which may or may not be the same as the web manager login and
password.
Execute and change the following:
1
Change
system-parameter ip-options
and specify under RTCP Monitor Server the:
• Default server IP address = the Application server IP address
• Default port = Must match what you put in your software
• Default RTCP Report Period = you can leave at default
• Enter/submit the changes
2
Change
ip-network-region x
(for every network region that pulls RTCP information)
• On page one, make sure that RTCP Reporting is enabled.
• Under RTCP monitor server Parameters,
–Use default server parameters (this uses the parameters you set up on the
system-
parameter ip-options
form)
–If you want to specify a separate server IP address, specify it under server IP address
and server port