Users Guide
Actions Portlet | Actions and Adaptive CLI
OMNM 6.5.3 User Guide 569
Valid Values
—Enter valid date values above the list, and click the green plus to add them to the
list.
Decimal
Default Value
—Enter a single or range of default decimal values.
Constraints
—Enter a range of acceptable numbers separated by a colon. For example, Constraints
= 2:4096. At runtime, a field where you can enter numbers. validates that entered numbers
are between 2 and 4096 when running the Adaptive CLI. If you enter a number outside this
range, a validation message appears and the attribute name turns red. You can also include
several numbers or ranges separated by the pipe (|) character. If you specify a range, the
lowest number must be to the left of the highest number. For example 9:99|999:1010.
Valid Values
—Enter valid decimal range values, and click the green + (the red - removes them).
You can manage these as described in
Coded Value
above.
IP Address
See also
Validating IP Address Variables
on page 570.
Default Value
—Enter a default IP Address.
Valid Values
—Enter valid values as described in
Coded Value
above. Check
IP Mask
,
Subnet,
Allow 32 Bit Mask,
and
Allow Any Valid Ip
in the
Properties
tab if you want the values
entered to be those.
Editable Valid Values
—Check to enable editing of default or entered IP addresses.
Integer
Default Value
—Enter a default integer.
Constraints
—Enter a range of acceptable numbers separated by a colon. You can also include
several numbers or ranges separated by the pipe (|) character. If you specify a range, the
lowest number must be to the left of the highest number. For example 9:99|999:1010.
Valid Values
—Enter ranges of valid values as described in
Decimal
above.
Editable Valid Values
—Check to enable editing of default or entered integer.
Long
Default Value
—Enter a default long.
Constraints
—Enter a range of acceptable numbers separated by a colon. You can also include
several numbers or ranges separated by the pipe (|) character. If you specify a range, the
lowest number must be to the left of the highest number. For example 9:99|999:1010.
Valid Values
—Enter ranges of valid values as described in
Decimal
above.
Inventory Reference
Select the Reference Type entity with the list that appears when you click the
green plus (+), then use the side-by-side widget’s arrows to move available
attributes from Available to Selected. You can change the Reference Type by deleting
it with the red minus (-), then selecting a new type with the green plus.
String
Default String
—Enter a default string.
Valid Values
—Enter valid values as described in
Coded Value
above.
Editable Valid Values
—Check to enable editing valid values.