Users Guide
Monitoring Network Availability | Performance Monitoring
386 OMNM 6.5.3 User Guide
The editor has the following fields and settings to configure:
Condition Properties
Name
— Enter a text identifier for the conditions.
Alert
— Check this if you want OpenManage Network Manager to emit an alert when the monitor
satisfies the conditions.
Trendable
— Check if the conditions specified are trendable. If this is true, the database retains
qualifying conditions (or thresholds) for later reporting/dashboards.
Severity
— Specify the severity of the emitted alert, if any.
Successive Intervals Required
— Enter the number of occurrences of what is specified in the
Condition Filter
to satisfy the Conditions.
Description
— A text description for the conditions.
Condition Filter
Minimally, use this panel to select a condition, an operator and a value. If you want to use the
logical AND or OR operators with a second condition, click the green plus (+), and select a second
condition, operator and value. For example,
Packet Out Errors
greater than 200
AND
ifSpeed
greater than 10000
can be a set of conditions that only has to occur once to satisfy this monitor’s
condition.
Click
Save
to accept your edits, or
Cancel
to abandon them.