324 OMNM 6.5.3 User Guide
3
Shut down an interface:
> shutdown
4
Bring up the interface
> no shutdown
5
Locate the
syslogNotification
event in the Event History portlet.
6
Look at the syslogText provided from the
shutdown
and
no shutdown
commands.
7
Extract the relevant port information with these messages.
syslogText.0: 6w6d1h: S5000_22: %STKUNIT0-M:CP %IFMGR-5-ASTATE_DN:
Changed interface Admin state to down: Te 0/20
syslogText.0: 6w6d1h: S5000_22: %STKUNIT0-M:CP %IFMGR-5-ASTATE_UP:
Changed interface Admin state to up: Te 0/20
8
Right-click to create a new Protocol Translation > Syslog rule in the Event Processing Rules
portlet to extract information.
9
Make sure that the filtering tab is not blank as you edit.
For this example set