Ethernet Link Discovery LimitationFor all Force10 devices, Dell
OpenManage Network Manager does not discover ethernet links when they are
attached to management port because the LLDP table on the device is not
populated. (20579)
Server Start Delay—The Windows tray icon may prematurely indicate
application server has started. Workaround: Wait for five minutes, and the
application server should start completely with the proper icon shown. (18778)
Virus Warnings—Two files installed with this product—
bash.exe
or
md5sum.exe
—may trigger warnings with some anti-virus software. If you get a
virus detection warning for these files during installation, take no action. You
may want to turn off virus detection while installing.
Installing on Windows 2012 must be in compatibility mode. Right-click the
win_install.exe
file (not the shortcut, but the file in the
NM
directory under
the installation source directory), and select the Compatibility tab. Check Run
this program in compatibility mode for ... then select either Windows 7 or Vista.
Command line installations are supported without any compatibility issues.
(22634)
Microsoft Windows 2008 Terminal Server is not supported. The installer becomes
non-responsive with Data Execution Prevention enabled. This option is disabled
by default on Windows Server 2008, but is enabled on a Windows Server 2008
machine running Terminal Server. (2310)
Uninstalling sometimes does not delete files in use. Examples can include the
following:
- Uninstalling can leave behind a folder or file in the installation director that
was open.
- If an oware prompt in a command shell is running the oware3rd directory can
remain after restart.
- If your system is slow to shutdown and release the Synergy or Oware services,
the oware/synergy or oware folder can remain after uninstall.
- The uninstaller itself is slow to shutdown and release its own resources. This
can result in the jre folder or the Uninstaller folder remaining after uninstall.
(23146)
The traffic flow analysis display does not wrap the names of devices listed in the
flow chart, so a published pdf of the chart may cut off names. (26545)
The Adaptive CLI editor does not apply changes made to all its tabs (Script
Content, Continue Pattern, Error Pattern and Value Extraction) when you click
Apply. The Close button may still erroneously apply changes in other than Script
content tab. Workaround: Delete any erroneously saved change, re-make the
Error Pattern or other changed tab, Apply changes for each tab, one at a time.
Then save the Adaptive CLI from the script edit screen. (hd-2919)
Network Dashboard portlet fails after the discovery of a WMI device.
Workaround: Restart application and/or web server. Fixed: Release 7.2.3. (25923)
Converged ethernet switches do not display their equipment type information in
network view (Topology) and the icon is different. Workaround: This
information appears in the Details panel. (24600)
You cannot filter port-based Adaptive CLIs based on device attributes like Vendor.
This means selecting Actions for a Force10 device port may display other vendors’
Adaptive CLIs (24332)