Owners Manual

Table Of Contents
Supported Dell Equipment
55
The following are supported Dell Networking FTOS S-Series models supported in a
stacking configuration:
S60, S55, S50N, S50V, S25N, S25P, S25V, S4810, S4820T, S5000.
Ports for the POE+ card C150/C300 also appear in the ports portlet (23884)
NOTE:
The latest OMNM version supports FTOS 9.4 and later. It discovers Dell Networking
FTOS Devices as Dell Networking Devices. The section of this document describing
New Features describes the manual procedures required if you upgrade to this version.
Known Issues for Dell Networking PCT, Dell Networking FTOS and Wireless devices
When deploying to a stacked N-Series, the device reports the following:
Stack port errors detected on the following interfaces”
This message causes the OMNM deploy process to state that the deploy failed.
(30279)
Workaround: Check the firmware version on the device to see if the upgrade
succeeded.
Dell Networking N Series devices “Firmware deploy” cannot be used to
downgrade the firmware from 6.5 to an older firmware image. This requires a
special process as outlined in the Dell documentation. (30718)
http://www.dell.com/support/home/us/en/04/product-support/product/
networking-n2000-series/drivers
As a part of firmware deployment on the Dell Networking N Series devices, the
firmware and boot code will be upgraded. CPLD update is not a part of the
deploy process. (30713)
The stacking ports are not being discovered for N15xx models due to information
missing in entPhysicalTable. (27347)
A duplicate device cannot be detected if they are in the same discovery profile or
range of IPs to be discovered. Detecting the duplicate device will only work when
one of the devices has already been discovered. (27942)
X-Series don't support "Boot system image-1" command. As a result, during
deployment process, device will reboot from device pre-selected boot image.
(27275)
Poweredge VRTX doesn't support memory KPI. (27430)
Poweredge VRTX - serial number not discovered. (27432)
Download firmware for dell powerconnect not functioning remove. (27438)
Despite job status for Dell Force10 TFTP configuration restores showing success,
you may see an Timeout error message. This message can be safely ignored.
(27013)
Because of a firmware bug, Layer 2 PowerConnect switches only support telnet
for all CLI based features, not SSH. (hd-2913)
For Dell Networking FTOS devices with firmware 9.6 installed, resync may display
an error on the command
show fc switch
. Workaround: With this firmware
you must enable the
fc
feature for the
show fc
command to work. Enable that
feature and resync works without error. (26481)
Upgrading from previous versions may produce a seeding error because a report
template (Dell S5000 Fabric Device Template) has changed. Workaround: Before