Owner's Manual

Data Policies 733
Policy Editor
-
Attribute Name
Select from the pick list. Options vary, depending on the
Entity Type
selected
at the top panel of this screen.
-
Threshold Type
Select from
High Threshold,
or
Low Threshold
, and enter the
High / Low
Value
and
High / Low Reset Value
. Reset values reset the data notification for the selected
parameter. If equipment exceeds the Low Threshold at 10, and something makes that
parameter 40 when the Low Reset value is only 30, then the application clears the Low
Threshold event.
Click
Save
to preserve your edits.
Data Policy Editor - Membership
This screen lets you manage the equipment membership monitored by your data policies.
Figure 27-3. Data Policy Editor - Membership
Click
Add
to select equipment where you want to apply the policy configured in the Data Policy
Editor - General screen. Select a piece of equipment and click
Remove
to delete it.
Click
Save
to preserve your edits.