Owner's Manual

339
RMON -> History Control
The RMON History Control screen contains information about samples of data taken from ports.
Figure 13-89. RMON History Control
Yo u c an
Edit
RMON History Control settings for the selected device in this screen. Click
Remove
to delete a selected, listed item. Click
Add
to create a new group of settings, or select an existing
interface listed in the upper portion of the screen and click
Edit
the editor opens (the lower portion
of the screen) with the following fields:
-
History Entry Number
.Entry number for the History Control Table.
-
Source Interface
Port or LAG from which the history samples were taken.
-
Sampling Interval (1-3600)
Indicates in seconds the time that samples are taken from the
ports. The possible values are 1-3600 seconds.
-
Sampling Requested
Number of samples to be saved. The default value is 50. ((1-65535)
NOTE:
A change to the number of sample is only effective after a reboot.
-
Current No. of Samples in List
The current number of samples taken.
-
Owner (0-20 characters)
RMON station or user that requested the RMON information.
Click
Apply
to accept the edits you have configured and add it to the list.
Cancel
abandons your
edits.