Owner's Manual

338
0.44 – 12.95Indicates that the port is assigned a power consumption level of 0.44 to 12.95
Watts.
0.44 – 3.8Indicates that the port is assigned a power consumption level of 0.44 to 3.8
Watts.
3.84 – 6.49Indicates that the port is assigned a power consumption level of 3.84 to 6.49
Watts.
6.49 – 12.95Indicates that the port is assigned a power consumption level of 6.49 to 12.95
Watts.
-
Powered Device
Enter text in the field. Provides a user-defined powered device description.
The field can contain up to 24 characters.
-
Overload Counter
A read-only display.
Indicates the total power overload
occurrences.
-
Short Counter
A read-only display. Indicates the total power shortage occurrences.
-
Denied Counter
A read-only display. Indicates times the powered device was denied power.
-
Absent Counter
A read-only display. Indicates the times the power supply was stopped to the
powered device because the powered device was no longer detected.
-
Invalid Signature Counter
A read-only display. Indicate the times an invalid signature was
received. Signatures are the means by which the powered device identifies itself to the PSE.
Signatures are generated during powered device detection, classification, or maintenance.
Click
Configure
to send any altered configuration to the device. Click
Refresh
to renew the device
information on this screen.