Notification Interval (seconds)
—Indicates that rate at which LLDP notifications are sent. The
possible field range is 5 - 3600 seconds. The default value is 5 seconds. (Does not appear for
all devices)
Click
Configure
to send any altered configuration to the device. Click
Refresh
to renew the device
information on this screen.
LLDP Port
The LLDP Port Settings let you define port types, states, and the type of information advertised for
ports selected.
Figure 13-71. LLDP Port
Yo u c an
Edit
port settings for the selected device in this screen. Click
Add
to create a port setting,
or select an existing port listed in the upper portion of the screen and click
Edit
the editor opens
(the lower portion of the screen) with the following fields:
-
Description
—The port name.
-
Admin Status
— Select the port type on which LLDP is enabled. The possible field values
include:
Tx Only–Enables transmitting LLDP packets only.
Rx Only–Enables receiving LLDP packets only.
Tx & Rx–Enables transmitting and receiving LLDP packets. This is the default value.