Release Notes

Versions/Systems Affected: All platforms
Issue 6
Data refresh in the Dell Dashboard widgets may be delayed after upgrade.
Description: After upgrading to Dell OpenManage Management Pack version 1.1/1.2, it is seen that there is a delay in the vROPS
console to populate the data in the Dell dashboard widgets. This is seen only after the upgrade and a hourglass is seen in the
widgets until the data is completely populated. Subsequent navigation to the widgets does not result in any delay.
Resolution: Logout and re-login will refresh the dashboard immediately.
Versions/Systems Affected: All platforms
Issue 7
Few Firmware objects are missing in the Dell views and reports.
Description: It is observed that some of the firmware objects reported to vROPS are not seen in the Dell views and reports.
Resolution: No Resolution.
Versions/Systems Affected: vROPS 6.5 and 6.6
Limitations
If the same Server or Chassis is managed by multiple OMIVV instances, then there will be multiple resources existing for the
same Server or Chassis.
After an upgrade to this version from 1.0 historical data for HDD will be discarded since a new resource type is created for it.
This new version of the adapter offers HDD and SSD data separately.
All non-healthy chassis component status are reported as critical only due to limitations in the query interface for retrieving
component health.
"Available Disk Space(GB)" is reported as -999 for PCIe SSD.
Adapter pak file is reported as "unsigned" by the vROPS admin client even though it is signed. Please delete the pak file and
try again for rectification.
When viewing the Dell dashboard on two browsers with different locales, some columns in the widgets on one browser may
show the string in column headers in a different language. This is a vROPS limitation. It will correct itself after the widget
refreshes itself. Alternatively, you may change the "Image redraw rate" setting in the widget for it to refresh sooner.
Whenever the Temperature Probes values are not available via iDRAC, the default value in vROPS for the CPU
MaxThreshold metric is 9999 and CPU MinThreshold metric is -999. The values remain same for both Celsius and
Fahrenheit.
14G servers with a single FAN configuration report the FAN redundancy health as Fully redundant instead of NA due to a
known issue in iDRAC.
Installation
Prerequisites
VMware vRealize Operations Manager version 6.5 or later.
OpenManage Integration for VMWare vCenter (OMIVV) version 4.0 or later.
Installation Procedure
For the installation instruction, see "OpenManage Management Pack for vRealize Operations Manager Version 1.2 Installation
Guide" at dell.com/openmanagemanuals.