Release Notes
Versions/Systems Affected: All platforms
Issue 6
Data refresh in the Dell Dashboard widgets may be delayed after upgrade.
Description: After upgrading to Dell OpenManage Management Pack version 1.1/1.2, it is seen that there is a delay in the vROPS
console to populate the data in the Dell dashboard widgets. This is seen only after the upgrade and a hourglass is seen in the
widgets until the data is completely populated. Subsequent navigation to the widgets does not result in any delay.
Resolution: Logout and re-login will refresh the dashboard immediately.
Versions/Systems Affected: All platforms
Issue 7
Few Firmware objects are missing in the Dell views and reports.
Description: It is observed that some of the firmware objects reported to vROPS are not seen in the Dell views and reports.
Resolution: No Resolution.
Versions/Systems Affected: vROPS 6.5 and 6.6
Limitations
● If the same Server or Chassis is managed by multiple OMIVV instances, then there will be multiple resources existing for the
same Server or Chassis.
● After an upgrade to this version from 1.0 historical data for HDD will be discarded since a new resource type is created for it.
This new version of the adapter offers HDD and SSD data separately.
● All non-healthy chassis component status are reported as critical only due to limitations in the query interface for retrieving
component health.
● "Available Disk Space(GB)" is reported as -999 for PCIe SSD.
● Adapter pak file is reported as "unsigned" by the vROPS admin client even though it is signed. Please delete the pak file and
try again for rectification.
● When viewing the Dell dashboard on two browsers with different locales, some columns in the widgets on one browser may
show the string in column headers in a different language. This is a vROPS limitation. It will correct itself after the widget
refreshes itself. Alternatively, you may change the "Image redraw rate" setting in the widget for it to refresh sooner.
● Whenever the Temperature Probes values are not available via iDRAC, the default value in vROPS for the CPU
MaxThreshold metric is 9999 and CPU MinThreshold metric is -999. The values remain same for both Celsius and
Fahrenheit.
● 14G servers with a single FAN configuration report the FAN redundancy health as Fully redundant instead of NA due to a
known issue in iDRAC.
Installation
Prerequisites
● VMware vRealize Operations Manager version 6.5 or later.
● OpenManage Integration for VMWare vCenter (OMIVV) version 4.0 or later.
Installation Procedure
For the installation instruction, see "OpenManage Management Pack for vRealize Operations Manager Version 1.2 Installation
Guide" at dell.com/openmanagemanuals.
4