Issues
• Servers that have an in-built PSU or the drives that are connected to Embedded Controller always display a warning status in
vROPS, because Embedded Controller is not monitored by iDRAC.
• The removed PSUs or fans exist under Dell chassis. In such a situation, because the health cannot be retrieved the FAN or PSU
status is displayed as Critical.
• Disconnecting the power cable and non-removal of PSU from a specic port of chassis results in the relationship maps displaying
the specic PSU as Critical. However, if the PSU is removed, the removed PSU is not displayed in the relationship map.
• The FAN Rollup status for PowerEdge FX2/FX2s and VRTX is based on the chassis rmware constraint. For more information,
see Chassis Management Controller User's Guide.
• When the chassis has an object down alert, the server may have a descendent alert, but the overall health status of the server
and relationship map are not impacted.
• Power supply unit health is not recorded for PowerEdge C6320.
• Alerts are not created when Non-Raid Physical Disk is removed from the server, and the Dell server overall health status is
displayed as Critical.
• Ensure that the basic health update and extended metric jobs are running successfully for the specied host, if the data is not
populated.
• The vROPS report displays the entries of a removed server. To generate an updated report, remove the non existent Dell objects
from inventory explorer.