Users Guide

Known Issues
Historical data for hard drive are not available after the OpenManage Management Pack for vRealize Operations Manager
Version 1.1 upgrade. This behavior is expected behavior with the latest upgrade, adapter is offering hard drive and SSD data
separately. However, historical data are available only for the SSD. Hard drive metrics are freshly populated since the time
adapter has been updated.
After OpenManage Management Pack for vRealize Operations Manager Version 1.1 upgrade, perform Stop Collecting and
Start Collecting for an adapter instance to reflect the correct hard drive metrics. In multiple instances, you need to
perform the same task for all adapter instances.
Firmware metrics collection does not happen. Run when the firmware catalog is getting refreshed. The inventory in OMIVV
again and check for the metrics after the next collect cycle.
Servers that have an in-built PSU or the drives that are connected to Embedded Controller always display a warning
status in vROPS, because Embedded Controller is not monitored by iDRAC.
The removed fans exist under DellEMC chassis. In such a situation, because the health cannot be retrieved the FAN status
is displayed as Critical.
Disconnecting the power cable and nonremoval of PSU from a specific port of chassis results in the relationship maps
displaying the specific PSU as Critical. However, if the PSU is removed, the removed PSU is not displayed in the
relationship map.
The FAN Rollup status for PowerEdge FX2 and VRTX is based on the chassis firmware constraint. For more information,
see Chassis Management Controller User's Guide.
When the chassis has an object down alert, the server may have a descendent alert, but the overall health statuses of the
server and relationship map are not impacted.
Power supply unit health is not recorded for PowerEdge C6320.
Alerts are not created when Non-Raid Physical Disk is removed from the server, and the Dell server overall health status is
displayed as Critical.
Ensure that the basic health update and extended metric jobs are running successfully for the specified host, if the data is
not populated.
The vROPS report displays the entries of a removed server. To generate an updated report, remove the nonexistent Dell
objects from inventory explorer.
If the PowerEdge MX server is managed using a chassis profile in OMIVV, power-related details in the extended metrics are
not visible. Following are the list of missing metrics:
Energy Consumption End Date time
Peak Amps End Date Time
Peak Amps Start Date Time
System Board Power Consumption Failure Threshold
System Board Power Consumption Warning Threshold
System Instantaneous Headroom
System Peak Amps
System Peak Headroom
System Peak Power End Date time
6
24 Known Issues