Owner's Manual
Utilities in Dell OpenManage IT Assistant 287
--#SUMMARY "Generic Critical Fan Failure"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
::= 262402
The conversion process is as follows:
EventCategory : Environmental
NOTE: IT Assistant has a set of pre-defined categories (Environmental, General
Redundancy, Keyboard-Video-Mouse (KVM), Memory, Physical Disk, Power,
Printers, Processor, Security, Storage Enclosure, Storage Peripheral, Storage
Software, System Events, Tape, Virtual Disk, and Other). The event could fall under
any of these categories. However, a new category can also be created.
EventSourceName : asfTrapFanSpeedProblem
Severity : Critical [--#SEVERITY]
NOTE: IT Assistant categorizes events under the following categories: Ok,
Warning, Critical, Information, and Unknown.
Format String : Generic Critical Fan Failure [--
#SUMMARY]
EnterpriseOID : .1.3.6.1.4.1.3183.1.1 (To get the
EnterpriseOID, compile the MIB, in this case "DcAsfSrv.mib", in MG-Soft or
any other MIB browser.)
GenericTrapId : 6
SpecificTrapId : 262402 [::=]
EventPackageName : ASF (You can get this information from the MIB.
Open the MIB. The EventPackageName is displayed within [--Begin
Definition].)
If there is no package present under which the EventSource falls, you can
provide a new category name.
The final entry in the text file will be similar to:
Environmental|asfTrapFanSpeedProblem|Critical|Generic
Critical Fan
Failure|.1.3.6.1.4.1.3183.1.1|6|262402|ASF
NOTE: In case the import file contains a non-existing category, the category will be
created.