Owner's Manual

UI and re-open it. [102193,163732]
* Power monitoring agent shows unknown status for devices if you
have selected only the Peak Amperage or Peak Power counters for the
task running on these devices. [171464]
* By default, root login through SSH is not enabled on VMware ESX
Servers. As a result, all IT Assistant tasks that use the root
account would fail. To enable the SSH root login on the ESX Server,
set the option "PermitRootLogin=YES" in "/etc/ssh/sshd_conf" file.
[174023]
* For systems with a Trusted Computing Group (TCG) 1.2-compliant
Trusted Platform Module (TPM) chip, software updates for BIOS will
fail if all of the following are true:
- The Microsoft Windows BitLocker Drive Encryption feature is
enabled.
- The TPM feature is set (using BIOS) to ON with Preboot
Measurement.
For information about TPM security settings, see the "Dell
OpenManage Server Administrator Online Help" or the
"Dell OpenManage Server Administrator User's Guide" available
on the Dell Support website at "support.dell.com" and on the
appropriate media supplied
by Dell.
For software updates for BIOS to function, perform the following
steps:
1. Disable the Microsoft Windows BitLocker Drive Encryption feature.
For information on disabling this feature, see the Microsoft
documentation at "www.microsoft.com."
2. Update BIOS.
3. Re-start the system.
4. Re-enable the Microsoft Windows BitLocker Drive Encryption
feature.
You can use IT Assistant to view the TPM information in the Device
Details page.
* You may not get appropriate privileges in the IT Assistant GUI if:
a) you are part of an Active Directory group, which is in turn part
of another group and
b) you launch Server Administrator using the desktop icon and
Single Sign-on is enabled. [167801].
* In the Online Repository Synchronization wizard, while testing
Internet connectivity, if the test passes, IT Assistant may use the
same Internet Connection settings and continue to report further
tests as successful even if you provide different proxy settings.