Known issues
Issue 1
Description
While installing OMIMSWAC by using local path or network path, multiple instances of OMIMSWAC extension may be listed
under Available and Installed Extensions. This happens when more than one .nupkg package is available in the specified folder
path, or the .nupkg packages are available in root or subfolders in addition to the folder path provided under Feeds > Add
package source.
Workaround
Ensure that a single .nupkg package is available in the root or subfolders under Feeds > Add package source.
Issue 2
Description
The hardware inventory attribute values of storage enclosure components might be empty because the information is not
available on the target iDRAC.
Issue 3
Description
If NICs are disabled in BIOS settings, there will be a delay in displaying the health and hardware inventory information for certain
iDRAC firmware versions.
Workaround
Ensure all the NICs are enabled in BIOS settings.
Issue 4
Description
When accessing Windows Admin Center (WAC) locally with domain credentials, DUP downloads may fail during target node or
cluster updates.
Workaround
Ensure to access the Windows Admin Center remotely using domain administrator credentials. Otherwise, use local
administrator credentials to access the WAC locally. For more information, see https://docs.microsoft.com/en-us/windows-
server/manage/windows-admin-center/plan/installation-options