Users Guide
Table Of Contents
- Dell EMC OpenManage Integration Version 1.1.1 with Microsoft Windows Admin Center User’s Guide
- Overview of OpenManage Integration with Microsoft Windows Admin Center
- Getting started with OpenManage Integration with Microsoft Windows Admin Center
- Ports required by Dell EMC OpenManage Integration with Microsoft Windows Admin Center
- Manage Dell EMC PowerEdge Servers
- Manage Failover Clusters and Azure Stack HCI
- View iDRAC details of the PowerEdge servers and nodes of HCI and Failover clusters
- Update PowerEdge servers and nodes of HCI and Failover clusters
- Configure the update compliance tools setting
- Update target nodes
- Update nodes of HCI and failover clusters
- Step 1: Generating compliance report—Target node components in Failover Clusters and Azure Stack HCI
- Step 2: Viewing compliance report and selecting components—Target node components in Failover Clusters and Azure Stack HCI
- Step 3: Updating—Target node components in Failover Clusters and Azure Stack HCI
- Troubleshooting
- Availability of OMIMSWAC extension logs
- Availability of update operation logs
- Unable to copy the required files to the target node to fetch inventory information.
- Unable to fetch the health and hardware inventory from iDRAC.
- Unable to complete or select the disks for the blink or unblink operations.
- Licensing status is Unknown or Non-licensed
- Job failed while downloading the required components for the server and cluster-aware updating operations.
- CredSSP failed during update
- Job failed while generating compliance report
- Job failed while updating the selected components.
- Identifying the generation of your Dell EMC PowerEdge server
- Contacting Dell EMC
- Glossary
- Appendix
Appendix
SAS-RAID_Driver
While performing update compliance operation for SAS-RAID_Driver, ensure that SATA controller and NVMe PCIe SSDs are set
to RAID mode. To configure RAID mode:
1. When the Dell Power-On Self-Test (POST) screen is displayed, press F2.
Dell PowerEdge System Setup window is displayed.
● Under System BIOS setting , configure RAID mode in SATA settings > Embedded SATA.
● Under System BIOS setting , configure RAID mode in NVMe settings > NVMe mode.
Recommended catalog for target nodes or clusters
The following table shows the recommended catalog for a target node or cluster under 'Update Source'.
Target nodes or cluster
Recommended catalog
PowerEdge server (Rack, Modular, and Tower) Online (HTTPs) - Dell EMC Enterprise Catalog (for
PowerEdge servers)
MX server Online (HTTPs) - Dell EMC MX Solution Catalog (for
PowerEdge servers)
AHCI cluster ready nodes (S2D or Ax appliance) Online (HTTPs) - Dell EMC Azure Stack HCI Solution Catalog
Cluster containing MX and PowerEdge server Online (HTTPs) - Dell EMC Enterprise Catalog (for
PowerEdge servers)
Cluster containing AHCI ready nodes and PowerEdge server Online (HTTPs) - Dell EMC Enterprise Catalog (for
PowerEdge servers)
Cluster containing PowerEdge, MX, and AHCI ready node
server
Online (HTTPs) – Dell EMC Enterprise Catalog (for
PowerEdge servers)
PowerEdge XE2420 Edge server or cluster Online (HTTPs) - Dell EMC Enterprise Catalog (for
PowerEdge servers)
B