Users Guide
Table Of Contents
- Dell EMC OpenManage Integration Version 1.1.1 with Microsoft Windows Admin Center User’s Guide
- Overview of OpenManage Integration with Microsoft Windows Admin Center
- Getting started with OpenManage Integration with Microsoft Windows Admin Center
- Ports required by Dell EMC OpenManage Integration with Microsoft Windows Admin Center
- Manage Dell EMC PowerEdge Servers
- Manage Failover Clusters and Azure Stack HCI
- View iDRAC details of the PowerEdge servers and nodes of HCI and Failover clusters
- Update PowerEdge servers and nodes of HCI and Failover clusters
- Configure the update compliance tools setting
- Update target nodes
- Update nodes of HCI and failover clusters
- Step 1: Generating compliance report—Target node components in Failover Clusters and Azure Stack HCI
- Step 2: Viewing compliance report and selecting components—Target node components in Failover Clusters and Azure Stack HCI
- Step 3: Updating—Target node components in Failover Clusters and Azure Stack HCI
- Troubleshooting
- Availability of OMIMSWAC extension logs
- Availability of update operation logs
- Unable to copy the required files to the target node to fetch inventory information.
- Unable to fetch the health and hardware inventory from iDRAC.
- Unable to complete or select the disks for the blink or unblink operations.
- Licensing status is Unknown or Non-licensed
- Job failed while downloading the required components for the server and cluster-aware updating operations.
- CredSSP failed during update
- Job failed while generating compliance report
- Job failed while updating the selected components.
- Identifying the generation of your Dell EMC PowerEdge server
- Contacting Dell EMC
- Glossary
- Appendix
For more information about setting the RAID mode, see Appendix
● Ensure that the WAC is not installed on the target node you want to update.
● Ensure that the target node is reachable using IP address, hostname, and Fully Qualified Domain Name (FQDN) of the target
node.
NOTE: If the target node is not reachable, and the target node update is performed, the update status may show
failed. In this case, if you reboot the target node immediately after update and rerun the compliance, the target node
components status may show compliant, whereas the overall target node update status may still show failed.
NOTE: Updating a target node where WAC is installed is not recommended. To support this scenario, install the WAC on
another target node (non WAC related) and complete the update.
NOTE: While the compliance or update is in progress, it is not allowed to run any further compliance or update task for the
same target node that includes the update requests from the MS WAC Update tools.
Step 1: Generating compliance report—Target node components
To generate a compliance report for a target node, select Update > Update Source, and choose any of the available offline or
online catalog options as follows:
Generating compliance report using online catalog
To use online catalog, OMIMSWAC must be connected to the Internet with or without proxy settings. OMIMSWAC with Internet
access allows you to use the online catalog option in the Update Source drop-down list to automatically download the catalog.
To view the compliance details, perform the following action:
1. Under Update > Update Source, choose any of the available online catalog options.
The corresponding online catalog is selected by default based on the target node.
Available online catalogs vary depending on the target node/cluster you are connected to as follows:
● For PowerEdge servers and clusters containing PowerEdge servers: Dell EMC Enterprise Catalog which contains the
validated versions of components for PowerEdge servers.
● For MX servers: Dell EMC MX Solution Catalog which contains the validated versions of components for PowerEdge MX
Modular.
● For Azure Stack HCI Cluster nodes: Dell EMC Azure Stack HCI Solution Catalog which contains the validated versions of
components for AX nodes and Storage Spaces Direct Ready Nodes.
For more information about available catalogs, see Appendix.
2. Select Next: Compliance details: to generate compliance report.
OMIMSWAC downloads the catalog, collects the DSU and IC tools that are configured in the Settings tab, and generates
a Compliance Report. If DSU and IC tools are not configured in the Settings, then OMIMSWAC downloads them from
www.downloads.dell.com to generate the compliance report.
The compliance details are computed and the report is available under Update > Compliance Details. For more details about
compliance report, see View compliance report.
Generating compliance report using offline catalog
OMIMSWAC with or without Internet access allows you to select the Offline - Dell EMC Repository Manager Catalog to
generate compliance report.
Before you generate the latest compliance report of target node components, ensure the followings. The following prerequisites
are required when OMIMSWAC is not connected to the Internet and the Offline-Dell EMC Repository Manager (DRM) catalog is
used to generate a compliance report and update components.
● Configure the share location details where the DSU and IC applications are placed. See Configure the update compliance
tools setting.
● Generate the latest catalog files by using the Dell EMC Repository Manager (DRM) application. The supported version of
DRM can be downloaded from Dell EMC Repository Manager.
To view the compliance details, perform the following actions:
Update PowerEdge servers and nodes of HCI and Failover clusters