Release Notes
Table Of Contents
- Dell EMC OpenManage Integration Version 1.1.1 with Microsoft Windows Admin Center Release Notes
- Release summary
- Compatibility
- Key features
- New in this release
- Fixed issues
- Known issues
- Instructions for installing Dell EMC OpenManage Integration with Microsoft Windows Admin Center
- Instructions for upgrading Dell EMC OpenManage Integration with Microsoft Windows Admin Center
- Identifying the generation of your Dell EMC PowerEdge server
- Contacting Dell EMC
- Open source licenses
Known issues
Issue 1
Description
Unable to retrieve the health and hardware inventory from the target iDRAC.
Workaround
Ensure that the following are enabled or available on the target node:
● The Redfish service is enabled.
● An iDRAC user slot is available.
● The SMB port 445 is open.
● For management of PowerEdge servers, ensure that OMIMSWAC uses an internal OS to iDRAC Pass-through interface. By
default, iDRAC will be reachable using the IP address 169.254.0.1/<Subnet> or 169.254.1.1/<Subnet>. However, if the host
has another network interface in the same subnet (For example, when tool like VMFleet is installed), OMIMSWAC might not
be able to communicate to the iDRAC from the host OS.
To resolve the conflict, log in to iDRAC and change the USB NIC IP address under the OS to iDRAC passthrough section. For
more information about assigning this IP address, see the iDRAC documentation on the Dell EMC support site.
● Ensure that the target node is not booted to Lifecycle Controller.
● Target node is not in the reboot state, or is powered-off.
● The USB NIC adapter is not disabled on the target node operating system.
Issue 2
Description
For YX3X and YX2X models of PowerEdge servers with firmware versions lesser than 2.60.60.60, and YX4X model of
PowerEdge Servers with firmware versions lesser than 3.30.30.30, information of the following components are not displayed:
● Health status: memory, storage controllers, storage enclosures, and physical disks.
● Hardware inventory: memory, storage controllers, storage enclosures, physical disks, network devices, and firmware.
Workaround
● Ensure that the YX3X and YX2X models of PowerEdge servers are updated with latest iDRAC version of 2.60.60.60 or later.
● Ensure that the YX4X model of PowerEdge Servers are updated with latest iDRAC version of 3.30.30.30 or later.
Issue 3
Description
The overall health status of the PowerEdge servers, failover cluster and HCI cluster might be displayed as critical or warning
even if the components of the nodes displayed on the Windows Admin Center are healthy.The health status of physical disks
attached to embedded SATA controller may be displayed as Unknown because iDRAC is unable to get the health information for
these disks.
Workaround
For more details on the components in critical health state, go to the respective iDRAC console.
Issue 4
Description
6
10 Known issues