Users Guide
Health status—Supported server components in
Microsoft failover clusters
On the Cluster - Dell EMC PowerEdge Server page, select the Health Status tab to view the overall health status of the Microsoft
failover cluster created with PowerEdge servers and the health status of the following server components of the nodes in Microsoft
failover clusters created with PowerEdge servers. Selecting critical or warning section in the overall health status doughnut chart displays
corresponding nodes and the components in the critical or warning state respectively.
• CPUs
• Memory
• Storage Controllers
• Storage Enclosures
• Physical Disks
• iDRAC
• Power Supplies
• Fans
• Voltages
• Temperatures
The health statuses are represented by using a doughnut chart. You can select different sections in the doughnut chart to filter the health
status of the components. For example, when you select the red section, components with critical health status are only displayed.
In a HCI cluster, if the different sections of the doughnut chart for individual components are selected, the respective nodes with the
component health status are listed. Expand the nodes to view the components in a particular health state.
NOTE:
For software storage controllers and physical disks attached to embedded SATA controller, the health inventory
status will always be displayed as "Unknown".
Hardware inventory—Supported server
components in Microsoft failover clusters
On the Cluster - Dell EMC PowerEdge Server page, select the Hardware Inventory tab to view the hardware inventory details of the
following server components of the nodes in Microsoft failover clusters.
• System
• Firmware
• CPUs
• Memory
• Storage Controllers
• Storage Enclosures
• Network Devices
• Physical Disks
• Power Supplies
• Fans
To view iDRAC details of target node, see View iDRAC details of the PowerEdge servers and nodes of HCI and Failover clusters.
NOTE:
Under Hardware Inventory, the attribute values of a few server components are displayed as blank because the
value might not be available in the server.
NOTE: Under Firmware inventory, for few network devices with multiple ports, since the applicable firmware version is
same for all ports, only a single port with the firmware version will be displayed.
NOTE: Information of few attributes of storage enclosures, firmware inventory, and memory component might not be
available for:
• 12th and 13th generation of PowerEdge servers.
• 14th generation of PowerEdge servers with iDRAC version lesser than 3.30.30.30.
12 Manage Microsoft Failover Clusters created with PowerEdge servers