Description
Inventory fetch of servers and cluster nodes fails with the error: Unable to initialize the OMIMSWAC extension.
Resolution
Ensure IPMI driver is installed and IPMI service is in the running state on the target node. For more information, see https://
www.dell.com/support/article/sln318718/dell-emc-openmanage-integration-with-microsoft-windows-admin-center-omimswac-fails-to-
query-host-information.
Issue 12
Description
If NICs are disabled in BIOS settings, there will be a delay in displaying the health and hardware inventory information for certain iDRAC
firmware versions.
Resolution
Ensure all the NICs are enabled in BIOS settings.
Issue 13
Description
When a cluster is connected by using Single Sign-on authentication, OMIMSWAC is unable to retrieve the inventory information and the
Windows Admin Center might be unresponsive.
Resolution
Connect the cluster by using the Manage as feature and by entering the cluster administrator account. For more information, see
https://docs.microsoft.com/en-us/windows-server/manage/windows-admin-center/use/get-started.
Issue 14
Description
For a Failover cluster connection, if you navigate out of the OMIMSWAC extension to access other Windows Admin Center tools,
Windows Admin Center turns into a blank page.
Resolution
To continue to use Windows Admin Center tools, refresh the web browser.
Known issues