Release Notes
While installing OMIMSWAC by using local path or network path, multiple instances of OMIMSWAC extension may be listed under
Available and Installed Extensions when more than one .nupkg package is available in the specified folder path, or the .nupkg packages are
available in root or subfolders in addition to the folder path provided under Feeds > Add package source.
Workaround
Ensure that a single .nupkg package is available in the root or subfolders under Feeds > Add package source.
Issue 5
Description
If the lockdown mode is enabled on YX4X model of PowerEdge Servers and above, inventory of health, hardware, and iDRAC fails with
the error: “Unable to create users on target iDRAC device.”
Workaround
Disable the lockdown mode on the target node managed by Dell EMC OpenManage Integration.
Issue 6
Description
The update compliance report might not be generated for the cluster nodes.
Workaround
• Ensure that the cluster service is running on the cluster node by using the Get -ClusterService PowerShell command.
• Ensure that the cluster node is not rebooting or powered-off.
Issue 7
Description
The hardware inventory attribute values of storage enclosure components might be empty because the information is not available on the
target iDRAC.
Issue 8
Description
Retrieving inventory from servers and cluster nodes fails with the error: Unable to initialize the OMIMSWAC extension.
Workaround
Ensure IPMI driver is installed and IPMI service is running on the target node. For more information on the requirement and solution, see
https://kb.dell.com/infocenter/index?page=content&id=SLN318718
Issue 9
Description
If NICs are disabled in BIOS settings, there will be a delay in displaying the health and hardware inventory information for certain iDRAC
firmware versions.
Workaround
Ensure all the NICs are enabled in BIOS settings.