Release Notes

NOTE: On consequent edits, modified dates are updated appropriately.
Issue 63
Description:
While discovering servers using IP Address Range and specifying the IP addresses to exclude, if you change any IP value specified in
the IP Address Range after specifying the IP address to exclude, the following error is displayed, The IP address range that
you want to exclude is not within the specified IP address range.
Workaround:
As a workaround, do not change the IP Address Range values after you have specified the exclude IP address range to discover the
servers.
Issue 64
Description:
While deploying Operational Template, if RAID is selected as Device Component, the attributes of hardware and software
components do not get updated in the target server.
Issue 65
Description:
In the Modular System View page, the Firmware Version is not displayed after restoring the MX7000 modular system which is
discovered in the previous version of OMIMSSC.
Workaround:
As a workaround, rediscover the MX7000 modular system to view the firmware version.
Issue 66
Description:
In the Maintenance Center page, if disk attached to AHCI controller is attempted for an update through cluster aware method, the
updated Post Successful Update Version of the disk component will not be reflected.
Workaround:
As a workaround, after the CAU job is completed, restart the cluster node or nodes where AHCI controller is an applicable update and
refresh the inventory.
Issue 67
Description:
In the Maintenance Center page, while performing Run Update using Cluster Aware Update method, user cannot update the
firmware version of operating system driver pack.
Workaround:
As a workaround, you can update the operating system driver pack from iDRAC console, or can directly run the DUP on the node
operating system.
Issue 68
Description:
In Modular Systems view, Operational Template Compliance Summary displays noncompliant with zero noncompliant attributes
for MX7000.
Cause:
If MX7000 discovered in OMIMSSC is at 1.10.00 firmware version, attributes present under following specified groups cannot be
configured using modular system type Operational Template and these attributes should be modified outside of
OMIMSSC.
LocalAccessConfiguration
TimeConfig
Power
SessionConfiguration
Workaround:
Recapture the Operational Template and rerun the compliance.
Issue 69
Description:
14