Dell EMC OpenManage Integration for Microsoft System Center Version 7.
1 OpenManage Integration Version 7.2 for Microsoft System Center Release Notes This document describes the features, known issues, and resolutions in OpenManage Integration Version 7.2 for Microsoft System Center (OMIMSSC). Topics: • • • • • • • • • • • Release type and definition Importance Platform(s) Supported What’s new? Fixes Installation prerequisites Upgrade instructions Known issues and resolutions Download instructions Contacting Dell Release type and definition OpenManage Integration Version 7.
Importance RECOMMENDED: Dell EMC recommends the customer to review specifics about the software update to determine if it applies to your system. The update contains changes that impact certain configurations, or provides new features that may/may not apply to your environment.
Known issues and resolutions • Issue 1 Description: If the test connection or enrollment fails, then you get an error message. Workaround: As a workaround, perform the following steps: • • • • Ping from OMIMSSC Appliance to enrolled SCCM or SCVMM server FQDN by logging in to OMIMSSC Appliance VM as a readonly user. If there is a response, then wait for some time and then continue with the enrollment.
SC2016 VMM RTM build 4.0.1662.0 Administrator console may crash when importing OMIMSSC console extension. Workaround: • As a workaround, upgrade SCVMM using the 4094925 KB article available at support.microsoft.com/kb/4094925, and then import the OMIMSSC console extension.
• • For second attempt, server IP address is blocked for 30 seconds. For third and subsequent attempts, server IP address is blocked for 60 seconds. You can reattempt server discovery with correct credential profile details after the IP address is unblocked. While discovering an 11th or 12th generation PowerEdge server with iDRAC versions prior to 2.10.10.
Description: Creating DRM update source on management server running on Windows 10 Operating System (OS) may fail, displaying the following error message: Failed to reach location of update source. Please try again with correct location and/or credentials. Refer the dlciappliance_main log in OMIMSSC Admin portal, if the error message displayed is: Unix command failed SmbException: com.dell.pg.tetris.business.samba.smbclient.
Firmware update job submitted from OMIMSSC to iDRAC fails, and the OMIMSSC main log displays the following error: JobQueue Exceeds the size limit. Delete unwanted JobID(s). Workaround: • As a workaround, manually delete the completed jobs in iDRAC, and retry the firmware update job. For more information about deleting jobs in iDRAC, see iDRAC documentation at dell.com/support/home.
• As a workaround, run the DISM command to clean up all previously mounted images in Microsoft console, and then retry to update the WinPE image. Issue 28 Description: Firmware updates applied on 11th generation of PowerEdge servers may fail due to incompatible versions of iDRAC and LC with the following error: WSMan command failed to execute on server with iDRAC IP . Workaround: • As a workaround, upgrade the iDRAC and LC to the latest versions, and then apply the firmware updates.
• • The antivirus or firewall may restrict the successful run of the WINRM command. See the following KB article for workaround: support.microsoft.com/kb/961804 Issue 34 Description: Hypervisor deployment fails displaying the following error message in activity log: • • • Error: Error while applying Hypervisor Profile to host . Failed with error : For input string: "" Information: Successfully deleted drivers from library share sttig..
• As a workaround, reset iDRAC, and then schedule the export server profile job. For more information, see iDRAC documentation available at dell.com/support. Issue 39 Description: After submitting the import server profile job in OMIMSSC , the job gets timed out after two hours. Workaround: As a workaround, perform the following steps: 1. Start the server, press F2, and then enter BIOS Settings. 2. Click System Setup, and select Miscellaneous Settings. 3. Disable F1/F2 Prompt on Error.
• If you are accessing local FTP using proxy credentials that are created by CCProxy server, then the local FTP site is not accessible. Issue 46 Description: • In BIOS Settings, the snoop mode attribute does not support ClusterOnDie option. Issue 47 Description: • While creating a logical switch or a hypervisor profile and selecting host groups in OMIMSSC, the groups are not listed in nested form as present in SCVMM.
Workaround: As a workaround, perform any one of the following: • • Select any other dependent attribute having pool value or the same dependent attribute and save the Operational Template. • Create a new Operational Template. Issue 54 Description: • If you delete multiple credential profiles, the SCVMM and OMIMSSC consoles may be unresponsive until the profiles are deleted.
NOTE: On consequent edits, modified dates are updated appropriately. • Issue 63 Description: While discovering servers using IP Address Range and specifying the IP addresses to exclude, if you change any IP value specified in the IP Address Range after specifying the IP address to exclude, the following error is displayed, The IP address range that you want to exclude is not within the specified IP address range.
In the Maintenance Center page, on performing import device profile, using vFlash as a Protection Vault, imported firmware version of few components may not reflect . Workaround: • As a workaround, perform a refresh inventory after successful import of device profile. Issue 70 Description: In Credential Profile page, the device credential profile can be edited and reused but cannot be deleted.