FAQ
Discovery, synchronization and inventory
scenarios in
OMIMSSC
Failure to discover servers
When multiple Microsoft consoles are enrolled to an OMIMSSC Appliance, and you try to discover a server, if even one of the SCCM
consoles are not reachable, then the server discovery job will fail.
As a workaround, de-enroll the SCCM console that is not reachable, or fix the errors and ensure that the SCCM console is reachable from
OMIMSSC Appliance.
Discovered servers not added to All Dell Lifecycle
Controller Servers collection
After discovering the servers in OMIMSSC for SCCM console extension, the server may not get added into All Dell Lifecycle Controller
Servers collection.
As a workaround, delete the All Dell Lifecycle Controller Servers collection and then discover the server. The collection is automatically
created in SCCM and the server is added to this group.
Failure to discover servers due to incorrect
credentials
If you provide incorrect credential details during discovery, then based on the iDRAC version, the following resolutions are available:
• • While discovering a 12th generation PowerEdge server with iDRAC version 2.10.10.10 and later, if incorrect details are provided in
the credential profile, the server discovery fails, with the following behavior:
• For first attempt, server IP address is not blocked.
• For second attempt, server IP address is blocked for 30 seconds.
• For third and subsequent attempts, server IP address is blocked for 60 seconds.
You can reattempt server discovery with correct credential profile details after the IP address is unblocked.
• While discovering an 11th or 12th generation PowerEdge server with iDRAC versions prior to 2.10.10.10, if server discovery
attempts fail due to incorrect credential profile details, then rediscover the server with the correct credential profile details.
• For iDRAC versions prior to 2.10.10.10, blocking of IP addresses is configurable. For more information, see iDRAC documentation at
Dell.com/idracmanuals. Based on your requirement, you can also disable blocking of IP addresses. And you can also check if the
iDRAC.IPBlocking.BlockEnable feature is enabled in iDRAC.
• If the default iDRAC credential profile is changed after a server is discovered and added in the Appliance, then no activity can be
performed on the server. To work with the server, rediscover the server with the new credential profile.
Creation of incorrect VRTX chassis group after
server discovery
When modular servers that were previously in another chassis are added to a VRTX chassis and discovered in OMIMSSC, the modular
servers carry previous chassis service tag information. Hence, a VRTX chassis group with old chassis information is created in the
Appliance instead of the latest chassis information.
As a workaround, do the following:
1. Enable CSIOR, and reset iDRAC on the newly added modular server.
6
Discovery, synchronization and inventory scenarios in OMIMSSC 13