Users Guide

Table Of Contents
Deploy Operational Templates
NOTE: Ensure that you do not enable attributes that change the credentials to log in to the device after deploying the
Operational Template.
1. In OMIMSSC, click Configuration and Deployment, and click Server View. Select the servers on which you have applied
the template, and then click Deploy Operational Template.
The Deploy Operational Template page is displayed.
2. In OMIMSSC, click Configuration and Deployment, and click Modular Systems View. Select the Modular System on
which you have assigned the template, and then click Deploy Operational Template.
The Deploy Operational Template page is displayed.
3. (Optional) To export all the attributes that are marked as pool values in the selected template to a .CSV file, click Export
Pool Attributes, else, go to step 4.
NOTE: Before exporting the pool values, add the IP address of the OMIMSSC Appliance where the OMIMSSC console
extension is installed, to the local intranet site. For more information about adding the IP address in IE browser, see
Browser settings section in Dell EMC OpenManage Integration for Microsoft System Center Version 7.2.1 for System
Center Configuration Manager and System Center Virtual Machine Manager User Guide.
4. If you have exported the pool values, enter values for all the attributes that are marked as pool values in the .CSV file and
save the file. In Attribute Value Pool, select this file to import it.
The format of a .CSV file is attribute-value-pool.csv
NOTE: Ensure that you select a .CSV file which has all proper attributes and the iDRAC IP or iDRAC credentials do not
change due to the template, since the job is not tracked by OMIMSSC after the iDRAC IP or iDRAC credentials changes
and is marked as failed though the job may be successful in iDRAC.
5. Enter a unique job name, description for the job, and click Deploy.
To track this job, the Go to the Job List option is selected by default.
Windows OS component for the OMIMSSC console
extension for SCCM
1. Select a task sequence and deployment method.
NOTE: Only the task sequences deployed on collections are listed in the drop-down menu.
For information about task sequence, see Task sequence.
2. Select one of the following options for the Deployment method:
Boot to network ISOreboots specified ISO.
Stage ISO to vFlash and Rebootdownloads the ISO to vFlash and reboots.
Reboot to vFlashreboots to vFlash. Ensure that the ISO is present in the vFlash.
NOTE:
To use the Reboot to vFlash option, the label name of the partition that is created on vFlash must be
ISOIMG.
3. (Optional) To use the image present in the network share, select the Use Network ISO as Fallback option.
4. enter an LC boot media image file.
5. Select the drivers required for the operating system.
Windows component for the OMIMSSC console
extension for SCVMM
Select Hypervisor Profile, Credential Profile, and Server IP from.
88
Configuration and deployment