Release Notes
As a workaround, do the following:
1. Delete the folder at default path: C:\Program Files\Microsoft System Center 2012 R2\Virtual
Machine Manager\Bin\AddInPipeline\AddIns\<username>
2. Restart SCVMM.
3. Remove the console extension, and then import the console extension as mentioned in Importing OMIMSSC console
extension for SCVMM section of Dell EMC OpenManage Integration for Microsoft System Center for System Center
Configuration Manager and System Center Virtual Machine Manager Installation Guide.
● Issue 38
Description:
While creating Storage Spaces Direct cluster, the Quality of Service policy for the Mellanox/Qlogic card on each cluster
node is recommended at 50% bandwidth to the SMB traffic, but the current setup is allocating only 30% bandwidth.
Workaround:
For information on how to configure QoS policy for SMB traffic, refer to Storage Spaces Direct deployment guide.
● Issue 39
Description:
Console Integration workflow triggered from DRM to connect to OMIMSSC appliance fails with password that includes
special characters such as, <,>,’,”,&
Workaround:
As a work around, change the appliance password from OMIMSSC black console to ensure the above mentioned special
characters are not part of the password.
● Issue 40
Description:
In the Maintenance Center page, even after updating Intel(R) Ethernet Converged Network Adapter X710 component the
current version will not be displayed as compliant with baseline version.
Workaround:
As a work around, login to iDRAC life cycle controller logs page to confirm if the Intel(R) Ethernet Converged Network
Adapter X710 component has been updated with the appropriate baseline version.
● Issue 41
Description:
Windows operating system deployment from SCCM console fails on Dell servers at "Format and Partition disk" step of task
sequence with PERC H730, H330 Adapter, H730 mini, H330 mini controller in BIOS boot mode.
Workaround:
As a work around, deploy windows operating system using WinPE image created with base image of SCCM without injecting
DTK drivers.
or
Deploy windows operating system in UEFI boot mode.
Limitations
● Issue 1
Description:
Operational Template compliance is not displayed for Active Directory attribute, since the attribute value is present in
managed device and not in Operational Template.
● Issue 2
Description:
OpenManage Integration Version 7.2.1 for Microsoft System Center Release Notes
13