Release Notes
○ Create a new Operational Template.
● Issue 26
Description:
After the firmware update of PowerEdge MX7000 components, the comparison report under Available Updates in the
Maintenance Center page, displays incorrect number of updates even if the firmware update is successful.
Workaround:
As a work-around, go to Maintenance Settings and click Test Connection of update source that is used while updating
the firmware. Go to Maintenance Center to view the correct number of updates.
● Issue 27
Description:
After de-enrolling SCVMM from the appliance, OMIMSSC page can still be opened through SCVMM console.
Workaround:
As a work-around, ensure to uninstall SCVMM console plug-in after de-enrolling SCVMM from the appliance.
● Issue 28
Description:
If the update source does not contain update for the selected device, the firmware update for complete MX chassis group
does not complete.
Workaround:
Ensure to select devices for which updates are available in the selected update source.
Or
Select only the devices that have applicable updates which are based on the selected update source for firmware update job
to complete.
● Issue 29
Description:
The Dell EMC Repository Manager (DRM) stops when repository of complete MX7000 chassis group is created using its
inventory.xml file.
Workaround:
Select only MX7000 chassis and servers. Ensure that the inventory does not contain IOMs and storage sleds.
● Issue 30
Description:
While discovering servers using IP Address Range and specifying the IP addresses to exclude, if you change any IP value
specified in the IP Address Range after specifying the IP address to exclude, the following error is displayed, The IP
address range that you want to exclude is not within the specified IP address range.
Workaround:
As a workaround, do not change the IP Address Range values after you have specified the exclude IP address range to
discover the servers.
● Issue 31
Description:
In the Modular System View page, the Firmware Version is not displayed after restoring the MX7000 modular system
which is discovered in the previous version of OMIMSSC.
Workaround:
As a workaround, rediscover the MX7000 modular system to view the firmware version.
● Issue 32
Description:
In the Maintenance Center page, if disk attached to AHCI controller is attempted for an update through cluster aware
method, the updated Post Successful Update Version of the disk component will not be reflected.
OpenManage Integration Version 7.2.1 for Microsoft System Center Release Notes