Server prole scenarios in OMIMSSC
This section has all the troubleshooting information related to exporting, and importing the server proles in OMIMSSC.
Failure to export server proles
After scheduling an export server prole job, the server prole is not exported, and the following error message is displayed: The
selectors for the resource are not valid.
As a workaround, reset iDRAC, and then schedule the export server prole job. For more information, see iDRAC documentation available at
dell.com/support.
Importing server prole job gets timed out after two
hours
After submitting the import server prole job in OMIMSSC, the job gets timed out after two hours.
As a workaround, perform the following steps:
1 Start the server, press F2, and then enter BIOS Settings.
2 Click System Setup, and select Miscellaneous Settings.
3 Disable F1/F2 Prompt on Error.
After performing the following steps, export the server prole again, and use the same server prole to import on that server.
10
24 Server prole scenarios in OMIMSSC