FAQ
As a workaround, check if the virtual switch is mapped to a physical switch, if the switch is congured correctly, and then connect to
OMIMSSC Appliance.
SCVMM crashes while importing OMIMSSC console
extension
SC2016 VMM RTM build 4.0.1662.0 Administrator console may crash when importing OMIMSSC console extension.
As a workaround, upgrade SCVMM using the 4094925 KB article available at support.microsoft.com/kb/4094925, and then import the
OMIMSSC console extension.
Failed to login to OMIMSSC console extensions
After logging in to OMIMSSC console extensions with dierent credentials used to login to Microsoft console, the login activity fails with
following error message: Username or Password is incorrect
As a workaround, login and launch Microsoft console with the credentials used to login to OMIMSSC console extension. This is a one-time
activity.
SC2012 VMM SP1 crashing during update
After upgrading to SC2012 VMM SP1, when importing OMIMSSC console extension to SC2012 VMM UR5 or later, the SCVMM console
may crash.
For information about this issue and resolving the issue, see issue 5 in the knowledge base URL: support.microsoft.com/kb/2785682.
As a workaround, update SCVMM irrespective of the version of the update rollup that is installed.
Install and upgrade scenarios in OMIMSSC