Release Notes

For more information about CSIOR, see the Troubleshooting section in the latest version of Dell Lifecycle Controller GUI User's Guide
available at dell.com/support/home.
Issue 26
Description:
After scheduling any job on a server belonging to a custom update group, if the server is deleted from Microsoft console and you
synchronize registered Microsoft console with OMIMSSC, the server is removed from the custom update group and the server is
moved to a predefined update group. You cannot delete such custom update group, because it is associated with a scheduled job.
Workaround:
As a workaround, delete the scheduled job from Jobs and Logs page, and then delete the custom update group.
Issue 27
Description:
When you try to update the WinPE image, update job may fail with the following error message: Remote connection to
console failed.
Workaround:
As a workaround, run the DISM command to clean up all previously mounted images in Microsoft console, and then retry to update
the WinPE image.
Issue 28
Description:
Firmware updates applied on 11
th
generation of PowerEdge servers may fail due to incompatible versions of iDRAC and LC with the
following error: WSMan command failed to execute on server with iDRAC IP <IP address>.
Workaround:
As a workaround, upgrade the iDRAC and LC to the latest versions, and then apply the firmware updates. The table lists out the latest
versions of LC and iDRAC.
Issue 29
Description:
After proving the details of a local update source, the test connection may fail as the required files may be not accessible.
Workaround:
As a workaround, ensure that catalog.gz file is present in the following folder structure.
For local HTTP update source: http:\\IP address\catalog\catalog.gz
For local FTP update source: ftp:\\IP address\catalog\catalog.gz
For local DRM update source: \\IP address\\catalog\<catalogfile>.gz
Issue 30
Description:
After deploying the Operational Template on the selected servers, the attributes or attribute values are not appropriate for the
selected .CSV file, or the iDRAC IP or iDRAC credentials are changed due to the configurations in the template. The job in iDRAC is
successful, however the status of this job in OMIMSSC is shown as unsuccessful or failure due to invalid .CSV file, or the job cannot
be tracked due to the iDRAC changes on the target server.
Workaround:
As a workaround, ensure the selected .CSV file has all the proper attributes and attribute values, and the iDRAC IP or credentials do
not change due to the configurations in the template.
Issue 31
Description:
The Deploy option is not displayed in an existing task sequence after uninstalling and reinstalling OMIMSSC console extension for
SCCM.
Workaround:
As a workaround, open the task sequence for editing, re-enable the Apply option, and click OK. The Deploy option is displayed again.
Issue 32
Description:
If the DHCP lookup fails while operating system deployment, then the server times out and the server is not moved into Managed
Lifecycle Controller Lifecycle Controller (ESXi) collection in SCCM.
8
Dell EMC OpenManage Integration for Microsoft System Center Version 7.1.1 for System Center Configuration Manager and System
Center Virtual Machine Manager Release Notes