Users Guide

After performing the following steps, schedule the export server prole job and use the same to complete the import server prole job
successfully.
Latest inventory information is not displayed even
after rmware update
Even though the rmware update job is complete on an 11th generation of PowerEdge server, in the Appliance, the inventory does not
display the latest rmware versions.
In the Appliance, refreshing the inventory is an activity performed immediately after a rmware update job is complete. Firmware update is
completed even before the PowerEdge server’s CSIOR activity is complete, due to which the earlier rmware inventory information is
displayed.
As a workaround, check if the CSIOR activity is complete in the PowerEdge server, and then in the Appliance, refresh the rmware
inventory. Also, ensure to restart the server after applying agent-free staged update. For more information on refreshing the inventory, see
Viewing and refreshing rmware inventory.
For more information on CSIOR, refer to the Troubleshooting section in the latest version of the Dell Lifecycle Controller GUI User's Guide
available at dell.com/support/home.
SCVMM error 21119 while adding servers to active
directory
While adding servers to Active Directory, SCVMM error 21119 is displayed. Error 21119: The physical computer with
<SMBIOS GUID> did not join Active Directory in time. The comptuer was expected to join Active
Directory using the computer name <host.domain>.
About this task
As a workaround, do the following:
Steps
1 Wait for some time to see if the server is added to the Active Directory.
2 If the server is not added to the Active Directory, then manually add the servers to the Active Directory.
3 Add the server in to SCVMM.
4 Once the server is added in to SCVMM, rediscover the server in OMIMSSC console extension for SCVMM.
The server will be listed under the Host tab.
Troubleshooting