Users Guide
After performing the following steps, schedule the export server prole job and use the same to complete the import server prole job
successfully.
Latest inventory information is not displayed even
after rmware update
Even though the rmware update job is complete on an 11th generation of PowerEdge server, in the Appliance, the inventory does not
display the latest rmware versions.
In the Appliance, refreshing the inventory is an activity performed immediately after a rmware update job is complete. Firmware update is
completed even before the PowerEdge server’s CSIOR activity is complete, due to which the earlier rmware inventory information is
displayed.
As a workaround, check if the CSIOR activity is complete in the PowerEdge server, and then in the Appliance, refresh the rmware
inventory. Also, ensure to restart the server after applying agent-free staged update. For more information on refreshing the inventory, see
Viewing and refreshing rmware inventory.
For more information on CSIOR, refer to the Troubleshooting section in the latest version of the Dell Lifecycle Controller GUI User's Guide
available at dell.com/support/home.
SCVMM error 21119 while adding servers to active
directory
While adding servers to Active Directory, SCVMM error 21119 is displayed. Error 21119: The physical computer with
<SMBIOS GUID> did not join Active Directory in time. The comptuer was expected to join Active
Directory using the computer name <host.domain>.
About this task
As a workaround, do the following:
Steps
1 Wait for some time to see if the server is added to the Active Directory.
2 If the server is not added to the Active Directory, then manually add the servers to the Active Directory.
3 Add the server in to SCVMM.
4 Once the server is added in to SCVMM, rediscover the server in OMIMSSC console extension for SCVMM.
The server will be listed under the Host tab.
Troubleshooting