Users Guide
As a workaround, delete all the les in Dell folder, and then schedule a rmware update job.
Failure of rmware update on 11
th
generation of
servers
A rmware update job started on 11
th
generation of PowerEdge servers may fail due to incompatible versions of iDRAC and LC with the
following error: WSMan command failed to execute on server with iDRAC IP <IP address>.
As a workaround, upgrade the iDRAC and LC to the latest versions and then start the rmware update job.
Failure of rmware update while using DRM update
source
The rmware update job may fail if you are using DRM update source with insucient access to the share folders. If the Windows
credential prole provided while creating DRM update source is not a part of domain administrator group or the local administrator group,
the following error message is displayed: Local cache creation failure.
As a workaround, do the following:
1 After creating the repository from DRM, right-click on the folder, click Security tab, and then click Advanced.
2 Click Enable inheritance and select the Replace all child object permission entries with inheritable permission entries from this
object option, and then share the folder with Everyone with read-write permission.
Failure of scheduled job on an update group
After scheduling a job on an update group, if all the servers are moved out of the update group and there are no servers present in the
update group then, the scheduled job fails.
As a workaround, cancel the scheduled job, add the servers to another update group, and then schedule a job on the update group.
Failure to apply Operational Template
After submitting the Deploy the Operational Template job on the selected servers, the attributes or attribute values are not appropriate for
the selected .CSV le, or the iDRAC IP or iDRAC credentials are changed due to the Template, then the job in iDRAC is successful.
However, the status of this job in OMIMSSC is shown as unsuccessful/fail due to invalid .CSV le, or the job cannot be tracked due to the
iDRAC changes on the target server.
As a workaround, ensure the selected .CSV le has all the proper attributes and attribute values, and the iDRAC IP or credentials do not
change due to the template.
Failure to access CIFS share using hostname
The modular servers may not be able to access the CIFS share using the host name for performing any job in OMIMSSC.
As a workaround, specify the IP address of the server having the CIFS share.
Failure to connect to FTP using system default update
source
After setting up and conguring, or upgrading the Appliance, trying to access the FTP site using system created update source Dell Online
Catalog might fail if proxy credentials are required.
Troubleshooting