Users Guide
Steps
1 In OMIMSSC, click Conguration and Deployment. Select the servers on which you want to deploy a template on, and then click
Deploy Operational Template.
The Deploy Operational Template page is displayed.
2 (Optional) To export all the attributes marked as pool values in the selected template to a .CSV le, click Export Pool Attributes, else,
go to step 3.
NOTE: Before exporting the pool values, add the IP address of the server where the OMIMSSC console extensions is
installed, to the local intranet site. For more information about adding the IP address in IE browser, see Browser
settings.
NOTE: If you have exported the pool values, provide all values for all the attributes marked as pool values in the .CSV
le and save the le. In Attribute Value Pool, select this le to import it.
NOTE: Ensure that you select a .CSV le which has all proper attributes and the iDRAC IP or iDRAC credentials do not
change due to the template, since the job is not tracked by OMIMSSC after the iDRAC IP or iDRAC credentials changes
and is marked as failed though the job may be successful in iDRAC.
NOTE: Download and install appropriate drivers from Dell.com/support if a yellow bang appears under Device Manager
after you deploy Windows 2016 OS on 12th generation of the PowerEdge servers.
3 Provide a unique job name, description for the job, and click Deploy. To view the jobs, Go to the Job List.
Unassigning Operational Template
1 In OMIMSSC , click Conguration and deployment.
2 Select the servers to unassign the template from, and then click Assign Operational Template and Run Compliance.
The Assign Operational Template and Run Compliance page is displayed.
3 Select Unassign from Operational Template drop-down menu, and click Assign.
Operational Template
39