Users Guide
• Update the Dell Default Collection before synchronizing OMIMSSC with SCCM. However, if an unassigned server is discovered in
SCCM, it is added to Import Dell server collection. To add this server in Dell Default Collection, add the server's iDRAC IP address in
the OOB page.
About this task
After synchronizing OMIMSSC with SCCM, if the server is not present in SCCM, then the All Dell Lifecycle Controller Servers collection
and the Import Dell server collection under Device Collections is created and the server is added to that respective group.
Synchronizing OMIMSSC console extension with
enrolled SCVMM
You can synchronize all Dell EMC Hyper-V hosts, Hyper-V host clusters, modular Hyper-V hosts, and unassigned servers from SCVMM
consoles with OMIMSSC console extension for SCVMM. Also, you get the latest rmware inventory information of the servers after
synchronization.
Consider the following points before synchronizing OMIMSSC with SCVMM:
• Synchronization uses the servers' default iDRAC credential prole details.
• If the host server’s Baseboard Management Controller (BMC) is not congured with the iDRAC IP address, then you cannot
synchronize the host server with OMIMSSC. Hence, congure BMC in SCVMM (for more information, see MSDN article at
technet.microsoft.com), and then synchronize OMIMSSC with SCVMM.
• SCVMM R2 supports numerous hosts in the environment, due to which synchronization is a long running task. Synchronization occurs
as follows:
• Hosts listed in the SCVMM environment are added to the Hosts tab in OMIMSSC Appliance.
• If a server is listed as an unassigned server and manually added to SCVMM, then after synchronization, the server is added in to the
Hosts tab of the OMIMSSC Appliance.
• If a host server belongs to a Hyper-V cluster, then the cluster details are available in the Hosts tab. The host server is added or
moved to the cluster update group and you can view this information in Maintenance Center page.
• If a host is a modular server, then the service tag of the chassis containing the modular server is added to the Hosts tab. If the
modular server does not belong to a Hyper-V cluster, the host server is added or moved in to the chassis update group and you can
view this information in the Maintenance Center page.
• Any changes to the host inventory details such as hostname, iDRAC IP address, memory, cluster membership, and so on are
updated in the Hosts tab.
• If a default update source is provided, then the rmware inventory is compared against the update source, and the latest
information is added to the update group.
Synchronizing with enrolled MSSC
In OMIMSSC, click Conguration and Deployment, and then click Synchronize with OMIMSSC to synchronize all the hosts listed in
enrolled MSSC with the
OMIMSSC Appliance.
Resolving synchronization errors
The servers that are not synchronized with OMIMSSC are listed with their iDRAC IP address and host name.
About this task
NOTE
: All servers that are not synchronized due to issues such as invalid credentials, or the iDRAC IP address, or connectivity, or
other issues; ensure that you resolve the issues rst, and then synchronize.
NOTE: During resynchronization, host servers deleted from the enrolled MSSC environment are moved to the Unassigned
Servers tab in the OMIMSSC console extensions. If a server is decommissioned, then remove that server from the list of
unassigned servers.
To resynchronize servers with credential prole issues:
Discovering servers and synchronizing with MSSC console
25