Release Notes
Description: After setting up and conguring, or upgrading OMIMSSC, trying to access the FTP site using system created update
source—Dell Online Catalog may fail if proxy credentials are required.
Workaround: As a workaround, to access the FTP site using Dell Online Catalog as an update source, edit the update source, and add
the proxy credentials.
• Issue 20
Description: When viewing LC logs, if you try to download the log les to .CSV format the download operation fails.
Workaround: As a workaround, add the Appliance FQDN in the browser under local intranet site. For information about adding the
Appliance in local intranet, see Browser settings section in Dell Lifecycle Controller Integration Version 2.0 for Microsoft System Center
User’s Guide.
• Issue 21
Description: After scheduling an export server prole job, the server prole is not exported, and the following error message is
displayed: The selectors for the resource are not valid.
Workaround: As a workaround, reset iDRAC, and then schedule the export server prole job. For more information, see the iDRAC
RACADM CLI Guide.
• Issue 22
Description: After collecting the LC Logs, when you view the LC Log le for a server the following error message is displayed: Failed
to perform the requested action. For more information see the activity log.
Workaround: As a workaround, reset iDRAC, and then collect and view the LC Logs. For more information, see the iDRAC RACADM
CLI Guide.
• Issue 23
Description: Same components on identical servers get updated during a rmware update irrespective of the selection of components
made on individual servers. This behavior is seen for 12th and 13th generation of the PowerEdge servers with the Enterprise license of
iDRAC.
Workaround: As a workaround, perform one of the following steps:
• To prevent irrelevant updates on identical servers, apply common components on identical servers and then apply specic
components separately on individual servers.
• Perform staged updates with planned outage times to accommodate the required rmware update.
• Issue 24
Description:
Hypervisor deployment is failing and the activity log displays the following error:Error New-SCVMHost failed with
following error : An out of band operation (SMASH) for the BMC <IP ADDRESS> failed on IDRAC
IP : <IP ADDRESS>
This error may occur due to either of these reasons:
• Dell Lifecycle Controller’s state is bad.
As resolution, log in to iDRAC user interface and reset Lifecycle Controller.
After resetting Lifecycle Controller, if you still face the problem try the following alternative.
• The anti-virus or rewall may restrict the successful run of the WINRM command.
See the following KB article for workaround: support.microsoft.com/kb/961804.