OpenManage Integration Version 7.
017 - 09
OpenManage Integration Version 7.0 for Microsoft System Center Release Notes This document describes the features, known issues, and resolutions in OpenManage Integration Version 7.0 for Microsoft System Center (OMIMSSC).
Previous versions DLCI for SCCM 3.3 and DLCI for SCVMM 1.3 Importance OPTIONAL: Dell EMC recommends the customer to review specifics about the software update to determine if it applies to your system. The update contains changes that impact certain configurations, or provides new features that may/may not apply to your environment. Platform(s) Affected 11th, 12th, 13th, and 14th generation of rack, modular, and tower models of Dell EMC PowerEdge servers.
Installation prerequisites You can install OMIMSSC on 11th generation and later generation of the PowerEdge rack, modular, and tower servers. You can manage servers using OMIMSSC if the servers are compliant. The following table lists out the prerequisites for servers to be managed by OMIMSSC. Managed servers are the servers managed using OMIMSSC. Table 1.
• • • • • ESXi 6.8 ESXi 6.5 ESXi 6.0 U3 ESXi 6.0 U2 (Not supported on 14th generation of the PowerEdge servers) ESXi 6.0 U1 (Not supported on 14th generation of the PowerEdge servers) NOTE: Deploying ESXi and RHEL operating systems are not supported on 11th generation of the PowerEdge servers. Also, see more system requirements for managed servers listed in OpenManage Integration for Microsoft System Center User’s Guide.
• • Add the Appliance IP and FQDN as a trusted site. • Add the Appliance IP and FQDN in Forward Lookup Zones and Reverse Lookup Zones in DNS. • Check if there are any error messages in C:\ProgramData\VMMLogs\AdminConsole file. Issue 6 Description: After creating the VM, and starting the OMIMSSC Appliance, the IP address is not assigned or displayed on the black console.
Workaround: As a workaround, restart the Appliance, and then create the update source of type HTTP or FTP. • Issue 12 Description: Firmware update jobs submitted from OMIMSSC to the iDRAC fail, and the OMIMSSC main log displays the following error: JobQueue Exceeds the size limit. Delete unwanted JobID(s). Workaround: As a workaround, manually delete the completed jobs in iDRAC, and retry the firmware update job. For more information on deleting jobs in iDRAC, see the iDRAC RACADM CLI Guide.
Description: After setting up and configuring, or upgrading OMIMSSC, trying to access the FTP site using system created update source—Dell Online Catalog may fail if proxy credentials are required. Workaround: As a workaround, to access the FTP site using Dell Online Catalog as an update source, edit the update source, and add the proxy credentials. • Issue 20 Description: When viewing LC logs, if you try to download the log files to .CSV format the download operation fails.
Description: Hypervisor deployment fails, and the activity log displays the following error: Error: Error while applying Hypervisor Profile to host . Failed with error : For input string: "" Information: Successfully deleted drivers from library share for Error: Deleting staging share (drivers) for failed. These errors may occur due to exception output by the VMM command-let GET-SCJOB status and driver files are retained in the library share.
b Click System Setup, and select Miscellaneous Settings. c Disable F1/F2 Prompt on Error. After performing the following steps, schedule the export server profile job and use the same to complete the import server profile job successfully. • Issue 30 Description: Even though the firmware update job is complete on an 11th generation of the PowerEdge server, the inventory list in OMIMSSC on Maintenance Center page does not display the latest firmware versions.
• Issue 36 Description: If you are accessing local FTP using proxy credentials created by CCProxy server, then the local FTP site is not accessible. • Issue 37 Description: In BIOS Settings, the snoop mode attribute does not support ClusterOnDie option. • Issue 38 Description: The action in comparison report for OS collector component is displayed as Downgrade even if it an upgrade action. Download instructions Download an evaluation version of the product from http://dell.